GY-V series intelligent battery charger adopts international advanced high frequency switch technology, with high efficiency, small volume, light weight, superior functions; The monitoring unit adopts centralized-distribution control manner, controlling risks to improve the reliability. Charger can provide both Chinese and English languages by clicking on the touch screen to set system parameters. With features of easy operation and convenient. Adopting intelligent operation management, multiple protections, greatly improve the stability and reliability of the system. Precisely manage of the charging voltage and current to ensure the batteries in the perfect condition and prolong the service life of the batteries. Adopting modular design, the system configures RS485 and CAN interfaces which can communicate with computers to monitor and control remotely according to user requirements, which is suitable for electric vehicle charging and all kinds of batteries.
Specification
Charger Series | GY-V Series Battery Chargers | |||||||||
Input voltage | 110V/220V/230V/240VAC±10% | 220VAC/380V/400V/460V/480VAC±10% | ||||||||
Input mode | Single phase | 3Phases/5 wires | ||||||||
Frequency | 47Hz-65Hz | |||||||||
Efficiency | >95%(100% load) | |||||||||
Power factor | >0.99(100% load) | |||||||||
Output voltage(VDC) | 24V | 36V | 48V | 72V | 80V | 110V | 120V | 200V | 220V | 500V |
Max charge current | 200A to 5A | |||||||||
Voltage accuracy | ≦1% | |||||||||
Current accuracy | ≦1% | |||||||||
Adjusted | Output voltage/current can be continuously adjusted | |||||||||
Protection | Input undervoltage protection,overvoltage protection,overcurrent protection,overheat protection,no battery protection,reverse connection,fan fault protection,shortcircuit protection,ect. | |||||||||
Humidity | 《93%RH | |||||||||
Temperature range | (-)30℃-(+)55℃ | |||||||||
Altitude | 0-4000m | |||||||||
Insulation voltage | Input to output:2500VDC/ for 1minute;input to chassis:2500VDC/ for 1min;output to chassis:2500VDC | |||||||||
Insulation resistance | Input/output to chassis>10MΩ ,at 250℃/60%RH humidity | |||||||||
Communication | RS232/RS485/Modubus/CAN2.0 optional | |||||||||
Remote monitoring | Yes, optional | |||||||||
Parallel function | Can be with parallel function optional | |||||||||
Discharge function | Can be with discharge function optional | |||||||||
Rectifier technology | Made with IGBT rectifiers or 6 or 12 pluse SCR thyristor full-bridge rectifiers optional | |||||||||
Cooling | Forced fan or water-cooling at high-temperature environment at desert | |||||||||
Noise | ≤55db | |||||||||
Color | RAL7032/Red/Green | |||||||||
MTBF | ≧100000 hours | |||||||||
Display | LCD touch screen,LED indicators,meters display,ect. | |||||||||
Compliance | IEC62040,IEC60146,GB/T-18487.1-2015,GB/T-20234.1-2015N, | |||||||||
Dimensions(mm) | 420x222x300mm |