HFC变频电源
Our HFC50 series marine frequency converters are designed with voltage 415V/440V/480V/690V/10KV/11KV/13.8KV/50Hz/60Hz and widely used for Navy,port,shipyard,dock,airport,radar,warship, factories,Oil,missile boat,submarine, cement factory,ect. Can be continuously working for 24 hours/365days without stop; Design life>25 years; MTBF>500000 hours
Introduction:
Our
HFC50 series marine frequency converters are designed with voltage
415V/440V/480V/690V/10KV/11KV/13.8KV/50Hz/60Hz and widely used for
Navy,port,shipyard,dock,airport,radar,warship, factories,Oil,missile
boat,submarine, cement factory,ect.
This series of products adopts
the design of large and forced air cooling system, and the equipment
cabinet is equipped with a detachable ABS resin dust-proof ventilation
filter. The equipment protection level reaches IP32, which meets the
design standards and specifications of marine equipment. This series of
products adopts standard module structure design, which can flexibly
carry out different equipment layout designs and a variety of single
power supply power capacity designs according to customer requirements.
The single power supply power capacity can reach 16 MVA. The series
product adopts the following proprietary technologies and
characteristics:
1.2 Adopting the special large force air cooling
technology and dust protection technology of the cabinet, the protection
level of the cabinet body reaches IP32 under the premise of ensuring
sufficient heat dissipation in the cabinet. This ensures that the
equipment is protected from the influence of dust and moisture in the
worse operating environment and can operate safely and reliably at 100%
full load for a long time.
1.4 The latest instantaneous voltage
waveform control technology is adopted. Output voltage fluctuation ≤ 0.5
V; The effective value of the output voltage changes
instantaneously(voltage temporary drop) when the load is suddenly added /
subtracted, ≤ 3% and returns to the rated output voltage value within
0.5 fundamental wave cycles.
The three-stage sinusoidal filtering
technology of inverter output is adopted. The output impedance of
sinusoidal filter is greatly reduced and the output power supply quality
is improved.
1.6 The master-slave synchronization parallel
technology is adopted. Realize the parallel operation of any multiple
variable frequency converters power supply equipments without
circulation.
The power switch device uses the fourth-generation SKIIP
IPM high-power intelligent power module produced by Semikron in
Germany; The main control chip uses DSP, the latest generation of TMS320
F28335-32-bit with floating-point motor control special digital signal
processing functions; The driving transmission mode adopts 5MHZ fiber
optic drive transmission; The inverter modulation method uses the latest
SVPWM space vector pulse width modulation method.
Filter hoisting
unit or 12 pulse rectifier Transformer: Using our own filter hoisting
technology, filter the input harmonic current of shore variable
frequency converter to reduce the harmonic interference to the input
grid.
6 pulse or 12 pulse rectifier module components: Adopt diode
rectifier module or Silicon controllable rectifier module + heat pipe
radiator + German EBM shaft flow cooling fan.
Inverse unit: Adopt the
fourth-generation SKIIP IPM intelligent power module from Germany+
Japan Nippon Chemi-con large-capacity electrolytic capacitor + flexible
laminated mother row + large centrifugal air cooling fan. The drive and
alarm signal of inverse unit are connected to the main control board
through optical fiber, and the running information of the inverse unit
is connected to the main control board through CAN bus, which greatly
improves the control performance of the inverse unit, the display of
operation information and the judgment and location of fault
information.
Cross-flow side blowing cooling fan: Adopt the long-life
cross-flow side hairdryer in China. The fan is installed in the cabinet
door with IP32 detachable cleaning ABS resin ventilation filter mesh to
inhale the indoor air outside the cabinet, and through the top of the
cabinet with large air centrifugal fan emits outside the cabinet, The
air circulation of the large amount of air required to be heat
dissipation in the cabinet.
Specification
Model | HFC5033-200 | HFC5033-250 | HFC5033-300 | HFC5033-400 | HFC5033-500 | HFC5033-600 | HFC5033-800 | HFC5033-1000 |
Capacity(KVA) | 200 | 250 | 300 | 400 | 500 | 600 | 800 | 1000 |
Input Voltage | 415V/440/690VAC±10%/10KV/13.8KV±10%,3phases,can be customized special voltage input according to customers' requirements | |||||||
Frequency | 50Hz±10%/60Hz±10% | |||||||
Phase | Single phase or 3phases+3wires | |||||||
Rectifier | 6pluses or 12pluses+PWM technology | |||||||
Power factor | 6pluses>0.95; PWM>0.99 | |||||||
THDi | <35%(6pluses at 100%load)or<5% (PWM at 100% load) | |||||||
Output Voltage | 440V/460V/480/690V/11KV/3Phases | |||||||
Current | 262A | 328A | 394A | 525A | 656A | 787A | 1050A | 1312A |
Capacity | 200KVA | 250KVA | 300KVA | 400KVA | 500KVA | 600KVA | 800KVA | 1000KVA |
Phase | Single phase or 3phases+3wires | |||||||
Voltage Stabilizing | <0.5V at static; <±1%(dynamic,0-100%load) | |||||||
Frequency | 50Hz/60Hz/400Hz (precision:0.01) | |||||||
Frequency stabilizing | <0.01%(0-100%load) | |||||||
Overload ability | 125% for 1minute; 150% stop output;can withstand 3 times of instant impact | |||||||
Total harmonic distortion of output voltage THDu | ≤1%(no load or line load ) | |||||||
Three phase output voltage imbalance | <1% | |||||||
Phase angle of three-phase output voltage | 120°(±0.1°) | |||||||
Efficiency | ≥95%(100%load) | |||||||
Inverter adjustment method | SVPWM space vector pulse width modulation method | |||||||
Voltage stabilizing control | Instantaneous voltage waveform feedback control method | |||||||
Inverter switch frequency | 3.6KHZ~6KHZ | |||||||
PWM Drive Transmission Mode | 5MHZ fiber drive transmission | |||||||
Master processor | 150MHz | |||||||
Display | LCD display or touch screen display | |||||||
Cold insulation resistance | ≥100MΩ | |||||||
Noise | ≤55dB(A) | |||||||
Environment | Ambient temperature is -5 °C to +45 °C, and the relative humidity is 0 to 95 °C,Working for 24 hours at 100% full load,the temperature in the equipment cabin is in the range of 25 °C ± 1 °C | |||||||
Protection Class | IP32 indoor type | |||||||
Cooling | Forced air | |||||||
Elevation | <1000M | |||||||
Dimension(LXWXH) | 1800*1500*2300 | 3400*1500*2300 | ||||||
Weight(KGS) | 1000 | 1500 | 2000 | 3000 | 4500 | 5000 | 5500 | 6000 |