Greencisco Industrial Co., Ltd.

Naval Frequency Converter

Our AC50 series marine frequency converters are designed and widely used for Navy,port,shipyard,dock,airport,radar,warship, factories,Oil,missile boat,submarine, cement factory,ect. Can be with RS485 communication,parallel function [ current-sharing function and when one frequency converter is working, the other frequency converter is standby],can be remotely monitored and controlled by customers' center monitor system. Can be continuously working for 24 hours/365 days without stop; output 50Hz/60Hz/400Hz is stable; Design life:25 years; MTBF>200000hours.

Characteristics

Introduction:
Our AC50 series marine frequency converters are designed and widely used for Navy,port,shipyard,dock,airport,radar,warship, factories,Oil,missile boat,submarine, cement factory,ect.
This series of products adopts the design of large and forced air cooling system, and the equipment cabinet is equipped with a detachable ABS resin dust-proof ventilation filter. The equipment protection level reaches IP32, which meets the design standards and specifications of marine equipment. This series of products adopts standard module structure design, which can flexibly carry out different equipment layout designs and a variety of single power supply power capacity designs according to customer requirements. The single power supply power capacity can reach 12 MVA. The series product adopts the following proprietary technologies and characteristics:
1.2 Adopting the special large force air cooling technology and dust protection technology of the cabinet, the protection level of the cabinet body reaches IP32 under the premise of ensuring sufficient heat dissipation in the cabinet. This ensures that the equipment is protected from the influence of dust and moisture in the worse operating environment and can operate safely and reliably at 100% full load for a long time.
1.4 The latest instantaneous voltage waveform control technology is adopted. Output voltage fluctuation ≤ 0.5 V; The effective value of the output voltage changes instantaneously(voltage temporary drop) when the load is suddenly added / subtracted, ≤ 3% and returns to the rated output voltage value within 0.5 fundamental wave cycles.
The three-stage sinusoidal filtering technology of inverter output is adopted. The output impedance of sinusoidal filter is greatly reduced and the output power supply quality is improved.
1.6 The master-slave synchronization parallel technology is adopted. Realize the parallel operation of any multiple variable frequency converters power supply equipments without circulation.
The power switch device uses the fourth-generation SKIIP IPM high-power intelligent power module produced by Semikron in Germany; The main control chip uses DSP, the latest generation of TMS320 F28335-32-bit with floating-point motor control special digital signal processing functions; The driving transmission mode adopts 5MHZ fiber optic drive transmission; The inverter modulation method uses the latest SVPWM space vector pulse width modulation method.
Filter hoisting unit or 12 pulse rectifier Transformer: Using our own filter hoisting technology, filter the input harmonic current of shore variable frequency converter to reduce the harmonic interference to the input grid.
6 pulse or 12 pulse rectifier module components: Adopt diode rectifier module or Silicon controllable rectifier module + heat pipe radiator + German EBM shaft flow cooling fan.
Inverse unit: Adopt the fourth-generation SKIIP IPM intelligent power module from Germany+ Japan Nippon Chemi-con large-capacity electrolytic capacitor + flexible laminated mother row + large centrifugal air cooling fan. The drive and alarm signal of inverse unit are connected to the main control board through optical fiber, and the running information of the inverse unit is connected to the main control board through CAN bus, which greatly improves the control performance of the inverse unit, the display of operation information and the judgment and location of fault information.
Cross-flow side blowing cooling fan: Adopt the long-life cross-flow side hairdryer in China. The fan is installed in the cabinet door with IP32 detachable cleaning ABS resin ventilation filter mesh to inhale the indoor air outside the cabinet, and through the top of the cabinet with large air centrifugal fan emits outside the cabinet, The air circulation of the large amount of air required to be heat dissipation in the cabinet.

Specification

Model

AC5033-6

AC5033-30

AC5033-40

AC5033-45

AC5033-75

AC5033-80

AC5033-100

AC5033-150

Capacity(KVA)

6

30

40

45

75

80

100

150

Input Voltage

220V/415V/440VAC±10%/10KV±10%,3phases,can be customized special voltage input according to customers’ requirements

Frequency

50Hz±10%/60Hz±10%

Phase

Single phase or 3phases+3wires

Rectifier

6pluses or 12pluses+PWM technology

Power factor

6pluses>0.95; PWM>0.99

THDi

<35%(6pluses at 100%load)or<5% (PWM at 100% load)

Output Voltage

115V/380V/400V/415V/440V/480V/690V/3Phases

Current

30A

150A

200A

226A

376A

402A

502A

753A

Capacity

6KVA

30KVA

40KVA

45KVA

75KVA

80KVA

100KVA

150KVA

Phase

Single phase or 3phases+3wires

Voltage Stabilizing

<0.5V at static; <±1%(dynamic,0-100%load)

Frequency

50Hz/60Hz/400Hz (precision:0.01)

Frequency stabilizing

<0.01%(0-100%load)

Overload ability

125% for 1minute; 150% stop output;can withstand 3 times of instant impact

Total harmonic distortion of output voltage THDu

1(no load or line load )

Peak coefficient of output voltage CF

1.4+0.1(No load)

Three phase output voltage imbalance

<1%

Phase angle of three-phase output voltage

120°±0.1°

Efficiency

95%(100load)

Inverter main circuit topology

Germany SKIIP fourth-generation half-bridge IPM intelligent power module constitutes a three-phase full-bridge inverter circuit

Inverter adjustment method

SVPWM space vector pulse width modulation method

Voltage stabilizing control

Instantaneous voltage waveform feedback control method

Inverter switch frequency

3.6KHZ6KHZ

PWM Drive Transmission Mode

5MHZ fiber drive transmission

Master processor

150MHz

Sinusoidal filtering method

Three-stage sinusoidal filter at output of inverter

Display

LCD display or touch screen display

Cold insulation resistance

100MΩ

Noise

55dBA

Environment

Ambient temperature is -5 °C to +45 °C, and the relative humidity is 0 to 95 °C,Working for 24 hours at 100% full load,the temperature in the equipment cabin is in the range of 25 °C ± 1 °C

Protection Class

IP32 indoor type

Cooling

Forced air

Elevation

<1000M

Dimension(LXWXH)
mm

600*500*1500

700*600x1900

900*100*2000

1000*1200*2000

Weight(KGS)

200

405

450

500

600

800

1000

1200